JMS-800D UltraFOCUS™ is an instrument focusing on ultramicro analysis,
which is optimal for dioxins in HRGC/HRSIM mode, as well as the related
compounds of PCB, PBDE, and POP compounds.
Double Column GC Interface (Option)
The UltraFOCUS™ has a double column GC interface to allow the simultaneous
connection of two GC injectors with separate GC columns. The pumping
configuration and capacity allows change of the GC column without venting the
instrument, reducing instrument downtime and increasing productivity. The unique
double column GC interface enables direct line of sight GC column setting into
the source region, as well as giving an improved thermal variation profile.
Ion Chamber
The socket Electron Ionization (EI) chamber allows rapid and convenient
change of ion chamber without venting the instrument.
Premier
MagnetThe magnet is made of fully laminated rolled grain-oriented steel
with high permeability and low hysteresis. The magnet design features an
extra-wide gap and so allows use of a wider flight tube, giving higher
transmission and reducing any susceptibility to contamination.
Detector
The UltraFOCUS™ uses a 20KV conversion dynode photomultiplier with 'point
detecting' technology, which ensures both stable longevity of the instrument and
sensitivity enhancement on compounds with m/z >500.
Information update ...
Ultra High Sensitivity
|
S/N 200 or more on 100fg 2,3,7,8-TCDD (R=10,000, HRSIM)
|
Ultra High Resolving Power
|
80,000 (10%Valley)
|
Highest Acceleration Voltage
|
10kV
|
Wide Mass Range
|
1-12,000u
|
Socket Type Ion Chamber
|
The Ion chamber is removable without venting for filament exchange and easy maintenance.
|
Standard Sample Inlet System
with Automatic On/Off Function
|
The software controls on/off switching of the inlet valve of the reservoir for the standard compound (PFK).
This reduces contamination of the ion source and maintains stable sensitivity for a long time.
|
Fully Computer-Controlled System
|
Incorporating easy operation functions for both automatic tuning of the ion source along with other optics,
and automatic resolution optimization of slit conditions.
Control of the mass spectrometer by the data system prevents mis-operation
and enables inexperienced operators to obtain optimum analysis results with ease.
|
Focus Tuning
|
Automated tuning for ion source lenses and Q poles is performed by one click of the mouse.
|
Resolving Power Setting
|
The mass resolving power is automatically adjustable by entering the target resolution numerically.
|
Dioxin Analysis Program (DioK)
*Option
|
The dedicated automatic quantitation program is based on the EPA method, JIS standard and EN protocol.
The DioK software provides high efἀciency in data processing work.
|
Auto Sampler
*Option
|
150 positions
|
Information update ...
JEOL retains service infrastructure to promptly and properly respond to the needs of our customer worldwide. We are aiming at service system that enables satisfactory and consistent service capability to any customer.