A superior gas chromatograph time-of-flight mass spectrometer (GC-TOFMS)
system that simultaneously accomplishes high-resolution analysis, high mass
accuracy, and high-speed data acquisition.
The AccuTOF GCx is the most advanced mass spectrometer system of the
AccuTOF GC series products.
The AccuTOF GCx provides solutions in a variety of applications.
Reliable determination of elemental compositionThe high-resolution and high
mass accuracy AccuTOF™ GCx enables accurate elemental composition determination,
which is a powerful tool for the qualitative analysis of unknown compounds and
impurities.
High resolution
High mass accuracy (at different concentrations, single ion)
Stable mass accuracy over time
High sensitivity
100 fg of octafluoronaphthalene (OFN) was measured continuously 8 times.
From the standard deviation of the EIC peak areas of OFN molecular ions, an
instrument detection limit (IDL) of 16 fg was calculated.
CV: Coefficient of variation IDL: Instrument detection limit
Wider mass rangeOligomer analysis with direct MS
The AccuTOF™ GCx, with a wide mass range and direct inlet system, can
analyze samples with large molecular weights that are difficult to handle with
GC.
A variety of ionization and sample introduction techniquesFI and FD - Ideal
soft ionization techniques for molecular weight determination
FI and FD are ionization techniques with a low level of internal energy in
molecular ions compared to EI and CI.
Being soft ionization techniques with minimum fragmentation, FI and FD are
ideal for molecular weight determination.
FI(Field Ionization)
The sample is introduced to the ion source through GC or a standard sample
inlet system.
Unlike CI, FI uses no reagent gas; no need to choose a reagent gas
appropriate for the analyte.
Molecular ions of fluorine compounds that are prone to fragmentation were
detected.
FD(Field Desorption)
The sample is applied onto the emitter and directly introduced to the
system.
Suitable for analysis of thermally labile compounds.
Ideal for samples soluble in nonpolar solvents.
Analyzes powder samples dispersible in solvents.
Analyzes low- to mid-polar metal complexes.
Analyzes high molecular weight samples not supported in GC/MS, such as
polymer.
Information on molecular weight was rapidly acquired from nonvolatile ionic
liquid.
EI/FI/FD combination ion source (optional)JEOL's unique ion source
combining EI, FI, and FD ionization allows for GC/EI, GC/FI, and FD analysis
without changing the ion source. The single ion source supports highly
productive analysis without breaking the vacuum.
Direct sample inlet system (optional)
2 types of direct sample inlet probes for different applications
EI and CI supported
DEP (Direct Exposure Probe)
Ideal for high boiling point/thermally unstable compounds
The sample, which is dissolved in a solvent, is applied to the filament at
the tip.
DIP (Direct Insertion Probe)
Ideal for high boiling point compounds/samples insoluble in solvent
A solid sample can be directly introduced to a dedicated glass sample tube
for analysis.
Qualitative analysis combining EI and FIThe EI mass spectrum allows for
library search. The elemental composition of fragment ions results in structural
information. Meanwhile, molecular ions detected in FI suggest the molecular
weight and elemental composition. By combining the information resulting from EI
and FI, one can achieve highly accurate qualitative analysis without relying
solely on library search. The combined technique is effective in qualitative
analysis of unknown components such as impurities.
EI/FI/FD combination ion source (optional)
JEOL's unique ion source combining EI, FI, and FD ionization allows for GC/EI, GC/FI, and FD analysis without changing the ion source. The single ion source supports highly productive analysis without breaking the vacuum.
Direct sample inlet system (optional)
2 types of direct sample inlet probes for different applications
EI and CI supported
DEP (Direct Exposure Probe)
-
Ideal for high boiling point/thermally unstable compounds
-
The sample, which is dissolved in a solvent, is applied to the filament at the tip.
DIP (Direct Insertion Probe)
-
Ideal for high boiling point compounds/samples insoluble in solvent
-
A solid sample can be directly introduced to a dedicated glass sample tube for analysis.
Qualitative analysis combining EI and FI
The EI mass spectrum allows for library search. The elemental composition of fragment ions results in structural information. Meanwhile, molecular ions detected in FI suggest the molecular weight and elemental composition. By combining the information resulting from EI and FI, one can achieve highly accurate qualitative analysis without relying solely on library search. The combined technique is effective in qualitative analysis of unknown components such as impurities.